Chemistry analyzer - Architect c4000

  • Model: Architect c4000
  • Manufacturer: Abbott Laboratories, USA

The ARCHITECT c4000 clinical chemistry analyzer demonstrates high-quality testing results and rapid STAT turnaround time. The ARCHITECT c4000 enhances laboratory productivity and provides users high confidence in clinical results.

The ARCHITECT c4000 clinical chemistry analyzer demonstrates high-quality testing results and rapid STAT turnaround time. The ARCHITECT c4000 enhances laboratory productivity and provides users high confidence in clinical results.

The ARCHITECT c4000 offers a maximum throughput of up to 800 tests per hour. Featuring a load-up capacity of 100 samples with 35 priority positions, the ARCHITECT c4000 allows for up to 90 refrigerated reagent positions on board, plus Integrated Chip Technology (Na+, K+ and Cl-).

For in vitro diagnostic use only.

DESCRIPTION 

Methods

Photometric, Potentiometric, Turbidimetric

Maximum Throughput

Up to 800 tests/hour

Sample Types

Serum, Plasma, Whole Blood, Urine, CSF

Sample Tubes

Height: 72-102 mm 

Diameter: 9.6-16.1 mm

Sample Cup

Yes (50 µl dead volume)

Sample Capacity

100

Sample Barcode Types

Code 39, Codabar, Interleaved 2 of 5, Code 128

Sample Result Storage

50,000

Sample Volume

1.5-35 µL, Average: 7.2 µL

Automatic Dilution

Yes

Sample Probe Carryover

<1000 ppm WB to WB

≤0.1 ppm WB to Serum

Reagent Capacity

Up to 90 refrigerated positions plus patented ISE (Na+, K+ and Cl-)

Reagent Type

>97% liquid ready-to-use

Reagent Onboard Stability

5-65 days, Average: 38 days

Calibration Frequency

1-60 days, Average: 25 days

Sample, Clot and Bubble Detection

Yes

Reagent Pressure Monitoring

Yes

Sample Interference Measurement

Yes: Hemolysis, Icterus, and Lipemia

System Control Center

1 SCC, with color touchscreen monitor, keyboard and mouse

Onboard Maintenance Records

Yes 

Online Error Code Help

Yes

Host Interface

Bidirectional, serial RS-232 interface, host query option available 

Remote Diagnostics

AbbottLink

Dimensions
(H x W x D)

49" x 63" x 36"

125.1 x 160 x 90.7 cm

Weight

1,132 lbs

513.5 kg

Electrical Requirements

AC 180-264V, 47-63 Hz, 20 amp

Water Requirements

Deionized water 15 liters/hour during normal operation, 25 liters/hour maximum

Heat Output*

3050 BTU/hr, running mode

Sample Loading

RSH

Contact infomation
Online Support
Hotline: (84) 898 200 377 -
Opening hours: 7h30 - 17h (Mon-Sat)
Facebook Fanpage
Copyright © 2023 TATA Medical Equipment and Pharmaceutical Trading Co., Ltd. All rights reserved